Design the facility as one system.

AI infrastructure brings together compute, electrical distribution, cooling and reliability. LIZO Blueprint helps engineering teams connect those design decisions in one structured model, evaluate constraints and compare alternatives before committing to a configuration.

01 / The engineering problem

The complexity is in the connections.

A data centre is not an isolated collection of racks, switchboards, transformers and cooling equipment.

Changes in compute density influence electrical capacity. Electrical distribution affects which loads can be supported. Cooling assumptions determine thermal headroom. Redundancy requirements change the equipment configuration and the capacity available during maintenance or failure.

When these decisions live in disconnected tools, their assumptions and revisions can drift apart.

LIZO Blueprint provides a structured engineering-model workspace that makes the relationships between modeled systems explicit.

Dependency diagramConceptual diagram: compute load drives electrical demand and heat; electrical distribution limits supportable load; cooling capacity limits thermal headroom; redundancy requirements constrain both electrical and cooling configurations. Computerack demand · density Electrical powersources · transformers · feeds CoolingCDU · chillers · headroom RedundancyN-1 · maintenance states electrical demandheat loadconfigurationcapacity in failureaux load

Conceptual design — explanatory diagram, not a product screenshot.

02 / What Blueprint provides today

One connected model for engineering decisions.

Equipment hierarchy

Organise infrastructure into site, building, data hall, rows, racks and connected electrical and mechanical equipment — the hierarchy the model actually stores.

Evidence: workspace screenshot →

Structured design workspace

Inspect equipment, edit supported properties and manage terminal definitions through the existing engineering interface.

Evidence: asset inspector →

Constraint-based calculations

Calculate values using configured parameters and deterministic rules. Identify capacity violations and missing information — values that are not supplied are shown as MISSING, not guessed.

Evidence: validation and calculations →

Scenario comparison

Compare supported changes against a baseline revision while preserving the original configuration.

Evidence: scenario comparison →

Traceable engineering outputs

Reports record the revision hash they were generated from, and values are tagged as valid, assumed or missing so reviewers can see what a conclusion rests on.

Evidence: design summary report →

Not offered as existing capabilities: certified protection or arc-flash analysis, iterative AC load flow, live hardware monitoring or control, protocol connectors (S7, BACnet, Modbus TCP, MQTT are modelled as “not implemented”), and automated construction design. Electrical studies in the AI-factory workspace are screening-level methods and require engineering review.

03 / High-density AI factory use cases

Designed for the systems behind AI infrastructure.

Modular deployment units

The AI-factory workspace represents repeatable deployment units and scalable units, so a change to unit capacity is evaluated across every instance instead of as unrelated designs.

Electrical distribution

Connect configured sources, transformers, switchboards, busways and rack feeds on a single-line diagram. Implemented checks include capacity loading, unit-checked power arithmetic, screening voltage drop and IEC 60909-style maximum three-phase short-circuit screening where impedance data is supplied.

Compute and cooling consistency

Modeled rack demand is carried into thermal assumptions; the workspace flags where configured IT heat exceeds the cooling capacity that has been entered, and leaves capacity MISSING where no value is supplied.

Resilience and energy scenarios

Explore N-1 equipment failures, fault isolation and restoration (FLISR) steps, battery energy balance and grid power-limit scenarios. These are modeled scenarios — not evidence of certified availability or real-world operating performance.

The Siemens DSX Vera Rubin NVL72 reference architecture is an example of the complexity that motivates this workflow; the workspace includes a reference template whose populated values cite the public brochure page they come from. LIZO does not supply Siemens hardware and does not reproduce a certified Siemens design.

Reference architectures inform the modeling approach. Each project requires its own equipment data, assumptions and engineering validation.

04 / Real product proof

See the model, not just the promise.

Every image below is a browser capture of the running LIZO Blueprint application. Projects shown are synthetic demonstration models — the application labels them as such on screen.

Synthetic dataIllustrative demonstration data — not live facility telemetry.

Proof A · Engineering workspace

A synthetic multi-hall facility open in the editor: the project hierarchy (site → building → data hall → rows → racks) on the left, the building layout with power and cooling connections in the canvas, and the live validation panel below.

LIZO Blueprint editor with a synthetic multi-facility project: hierarchy tree, building layout canvas with electrical connections and a validation panel listing missing and assumed values
LIZO Blueprint · Design workspace
Working product demonstrationIllustrative demonstration using synthetic data

Real editor screen. The project is labelled DEMONSTRATION DATA in the app.

Proof B · Property and terminal editing

Selecting a modeled asset opens the inspector, where its supported properties and terminals can be reviewed and edited. Each value carries its status (valid, assumed or missing).

LIZO Blueprint asset inspector showing properties and terminal definitions for a selected piece of equipment
LIZO Blueprint · Asset inspector
Working product demonstrationIllustrative demonstration using synthetic data

Real inspector screen on the synthetic demonstration project.

Proof C · Constraint evaluation

Calculations run deterministically on configured parameters. The validation view lists invalid values, incomplete topology and unsupported calculations, and the calculations view shows each calculation run with its inputs.

LIZO Blueprint validation view listing errors, warnings and assumed values for the demonstration model
LIZO Blueprint · Validation
Working product demonstrationIllustrative demonstration using synthetic data

Real validation output for the synthetic model.

LIZO Blueprint calculations view showing calculation runs with their inputs and results
LIZO Blueprint · Calculations
Working product demonstrationIllustrative demonstration using synthetic data

Real calculation runs on the synthetic model.

Proof D · Scenario comparison

A recorded baseline revision (R1) compared with a “high density halls” scenario: the application reports which sections changed — for example a UPS rating from 500 kW to 750 kW and rack design load from 8 kW to 12 kW — while the baseline stays intact. Both revisions are identified by hash.

LIZO Blueprint comparison of baseline revision R1 against a high density halls scenario, listing equipment counts, changed ratings and IT load assumptions
LIZO Blueprint · Scenario comparison
Working product demonstrationIllustrative demonstration using synthetic data

Real comparison report between two recorded revisions of the synthetic project.

Proof E · Traceable engineering output

The design summary report is generated from a recorded model revision and shows the values it was built from, including which are assumptions.

LIZO Blueprint design summary report generated from a recorded model revision
LIZO Blueprint · Design summary report
Working product demonstrationIllustrative demonstration using synthetic data

Real generated report for the synthetic project.

AI-factory workspace (DEMO template)

The AI-factory workspace inside Blueprint: single-line diagram with a transformer selected in the inspector, thermal checks and N-1 / FLISR scenario simulation. The model is the DEMO template and is badged DEMO DATA in the application.

AI-factory single-line diagram with a transformer selected and its parameters in the inspector, DEMO DATA badge visible
LIZO Blueprint · AI factory · SLD
Working product demonstrationIllustrative demonstration using synthetic data

Real screen, DEMO template.

AI-factory simulation tab showing N-1 failure results and FLISR restoration steps on the DEMO model
LIZO Blueprint · AI factory · Simulation
Working product demonstrationIllustrative demonstration using synthetic data

Modeled scenario on DEMO data — not measured performance.

Why no public interactive demo? The Blueprint application sits behind sign-in, and exposing its calculation engine on the public website would require a secure, isolated demo integration that does not exist yet. Rather than build a disconnected imitation, this page shows authentic captures. Request a guided demonstration.

05 / Commercial engagement

Start with one engineering workflow.

  1. 01

    Assess

    Identify one active engineering problem, review the relevant workflow and determine the required inputs, integration boundaries and evaluation criteria.

  2. 02

    Pilot

    Scope a bounded workflow using agreed equipment data, known assumptions and a specific evaluation objective.

  3. 03

    Evaluate

    Review the resulting model, calculations, limitations and workflow fit against criteria agreed with you.